MECHANICAL
Standard Crystal Vision module 266mm
x 100mm
Weight: 27g
Power consumption: 6.25 Watts
ANALOGUE INPUT
Digital input may be timed to an external analogue
reference or free run with no reference
Mixed syncs input 300mV to 2 volt or 300mV Black
and Burst into 75ohm
Auto or manual 625/525 line selection
Reference loop-through available
Free-run frequency + or - 15 ppm
OUTPUTS
2 SDI outputs using the RM01 frame rear module
270Mbit to EBU 3267-E and SMPTE 259M
ADJUSTMENTS
0 to 1 line adjustment of horizontal picture
position from syncs in 74ns steps
0 to 624 lines adjustment of vertical picture
position in 1 line steps for PAL
0 to 524 lines adjustment of vertical picture
position in 1 line steps for NTSC
BLANKING
To 601 specification vertically
1 test pattern is available with signals on
vertical lines 7 to 22 and 320 to 335 in PAL
and 10 to 20 and 273 to 282 in NTSC
TEST PATTERNS
32 digital test patterns plus a full frame logo,
divided into seven pattern banks - 100% Color
Bars, EBU Color Bars, 95% Color Bars, Split
Bars; Peak White, Black, Hard Grey, Red, Field
1 Only, Field 2 Only; Luma Only Ramp, Valid
Ramp, Limit Ramp, 10 Bit Blue Ramp, Shallow
Ramps, Steps, Modulated Ramp; Luma Only Multi-frequency
Burst, Multi-frequency Burst, Luma Only Frequency
Sweep, Frequency Sweep, Bow Tie; Mixed Selection
of Patterns, SDI Test, Pulse and Bar, Edge of
Frame Markers, Cross Hatch; PLUGE, SPLUGE, Co-site,
50Hz Rectangle, Safe Area; Crystal Vision Logo
A section of each test pattern can be made to
rotate to create a moving pattern
GPI INPUTS
Pattern bank selection
LED INDICATION OF:
Power supply present, PAL/NTSC standard, board
configured and ready for use, valid reference
syncs input detected
LOCAL CONTROL
Rotary switch selection of pattern banks, static
patterns and rotating patterns. Piano switch
selection of line standards (when no reference
syncs), EDH transmission, Y only or C only,
horizontal and vertical delay adjustments
REMOTE CONTROL
RS422/485 and RS232
19200 baud 8 bits, 1 stop no parity
Remote control of pattern selection, 10 non-volatile
user memory locations, Y only or C only, pattern
rotation, horizontal and vertical delay adjustments